← Tools
Tool
UM Eligibility Check | PlateLabs
Quick checklist to determine whether your pressure vessel qualifies for the UM (miniature) ASME Section VIII Division 1 code symbol stamp.
Question 1
Does the vessel meet the UM size limits — internal volume ≤ 1.5 ft³ AND MAWP ≤ 250 psi, OR internal volume ≤ 5 ft³ AND MAWP ≤ 100 psi?
Question 2
Is the vessel shop-built from materials permitted for UM construction?
Question 3
Is the vessel free from lethal service per UW-2(a)?
Question 4
Will the vessel be inspected by a qualified UM Authorized Inspector?
Question 5
Will the manufacturer prepare an ASME Form U-1A or U-1B Manufacturer's Data Report?